Blockless PLC Splitter
Fiber Optic PLC Splitter is an essential passive component in Fiber to the Home network.
The full name of the PLC Splitter is Planar Lightwave Circuit Splitter. It adopts silica optical waveguide technology and is used for optical power allocation from the central office to customer premises in FTTx and FTTH networks.
A Blockless Fiber PLC Splitter is a type of optical splitter that utilizes a Planar Lightwave Circuit (PLC) chip to divide a single optical input into multiple outputs. It is called “blockless” because it does not require a separate housing or block to protect the splitter chip. Instead, it features a compact and robust design that integrates the splitter chip directly into the fiber optic cable itself.
Features:
- Uniform power splitting
- Compact package dimension
- Low polarization-dependent loss
- Good channel-to-channel uniformity
- Low Insertion Loss and High Return Loss
- Environmentally and mechanically stable
- Wide operating wavelength range from 1260nm to 1650nm
Applications of Blockless Fiber PLC Splitter:
- Fiber-to-the-Home (FTTH) Networks
- Data Centers
- Telecommunication Networks
Standards:
- Telcordia GR-1209 and GR-1221
Specifications:
Table 1: Performance for 1×N PLC Splitter
Note: All measurements are done at room temperature without connectors.
Port Configuration | 1×2 | 1×4 | 1×8 | 1×16 | 1×32 | 1×64 | |
Operating Wavelength (nm) | 1260~1650 | ||||||
Insertion Loss (dB) | Typ. | 3.6 | 6.8 | 10.0 | 13.0 | 16.0 | 19.5 |
Max. | 4.0 | 7.3 | 10.5 | 13.7 | 16.9 | 21.0 | |
Loss Uniformity (dB) | Typ. | 0.4 | 0.5 | 0.5 | 1.0 | 1.0 | 1.5 |
Max. | 0.6 | 0.6 | 0.8 | 1.2 | 1.5 | 2.5 | |
Return Loss (dB) | 55 | 55 | 55 | 55 | 55 | 55 | |
PDL (dB) | Typ. | 0.1 | 0.1 | 0.1 | 0.1 | 0.2 | 0.2 |
Max. | 0.2 | 0.2 | 0.3 | 0.3 | 0.3 | 0.4 | |
Directivity (dB) | 55 | 55 | 55 | 55 | 55 | 55 | |
Fiber Length (m) | 1.0 or customized | ||||||
Fiber Type | Corning SMF-28e or customized | ||||||
Wavelength Dependent Loss (dB) | Typ. | 0.2 | 0.2 | 0.2 | 0.3 | 0.3 | 0.3 |
Max. | 0.3 | 0.3 | 0.3 | 0.5 | 0.5 | 0.5 | |
Temperature Stability (-40~+85°C) (dB) | Typ. | 0.3 | 0.3 | 0.3 | 0.4 | 0.4 | 0.4 |
Max. | 0.5 | 0.5 | 0.5 | 0.5 | 0.5 | 0.5 | |
Operating Temperature (°C) | -40~+85°C | ||||||
Storage Temperature (°C) | -40~+85°C |
Table 2: Performance for 1×N PLC Splitter
Note: All measurements are done at room temperature with connectors.
Port Configuration | 1×2 | 1×4 | 1×8 | 1×16 | 1×32 | 1×64 | |
Operating Wavelength (nm) | 1260~1650 | ||||||
Insertion Loss (dB) | Typ. | 4.0 | 7.0 | 10.3 | 13.5 | 16.5 | 20.0 |
Max. | 4.5 | 7.7 | 11.0 | 14.2 | 17.5 | 21.5 | |
Loss Uniformity (dB) | Typ. | 0.4 | 0.5 | 0.5 | 1.0 | 1.0 | 1.5 |
Max. | 0.6 | 0.6 | 0.8 | 1.2 | 1.5 | 2.5 | |
Return Loss (dB) | 55 | 55 | 55 | 55 | 55 | 55 | |
PDL (dB) | Typ. | 0.1 | 0.1 | 0.1 | 0.1 | 0.2 | 0.2 |
Max. | 0.2 | 0.2 | 0.3 | 0.3 | 0.3 | 0.4 | |
Directivity (dB) | 55 | 55 | 55 | 55 | 55 | 55 | |
Fiber Length (m) | 1.0 or customized | ||||||
Fiber Type | Corning SMF-28e or customized | ||||||
Wavelength Dependent Loss (dB) | Typ. | 0.2 | 0.2 | 0.2 | 0.3 | 0.3 | 0.3 |
Max. | 0.3 | 0.3 | 0.3 | 0.5 | 0.5 | 0.5 | |
Temperature Stability (-40~+85°C) (dB) | Typ. | 0.3 | 0.3 | 0.3 | 0.4 | 0.4 | 0.4 |
Max. | 0.5 | 0.5 | 0.5 | 0.5 | 0.5 | 0.5 | |
Operating Temperature (°C) | -40~+85°C | ||||||
Storage Temperature (°C) | -40~+85°C |
Table 3: Performance for 2×N PLC Splitter
Note: All measurements are done at room temperature without connectors.
Port Configuration | 2×2 | 2×4 | 2×8 | 2×16 | 2×32 | 2×64 |
Operating Wavelength (nm) | 1260~1650 | |||||
Insertion Loss (dB) | 4.0 | 7.6 | 11.0 | 14.5 | 17.5 | 21.0 |
Loss Uniformity (dB) | 0.8 | 1.5 | 1.5 | 2.0 | 2.5 | 2.5 |
Return Loss (dB) | 55 | 55 | 55 | 55 | 55 | 55 |
PDL (dB) | 0.2 | 0.2 | 0.4 | 0.4 | 0.4 | 0.4 |
Directivity (dB) | 55 | 55 | 55 | 55 | 55 | 55 |
Fiber Length (m) | 1.0 or customized | |||||
Fiber Type | Corning SMF-28e or customized | |||||
Wavelength Dependent Loss (dB) | 0.5 | 0.5 | 0.5 | 0.5 | 0.5 | 0.5 |
Temperature Stability (-40~+85°C) (dB) | 0.5 | 0.5 | 0.5 | 0.5 | 0.5 | 0.5 |
Operating Temperature (°C) | -40~+85°C | |||||
Storage Temperature (°C) | -40~+85°C |
Table 4: Performance for 2×N PLC Splitter
Note: All measurements are done at room temperature with connectors.
Port Configuration | 2×2 | 2×4 | 2×8 | 2×16 | 2×32 | 2×64 |
Operating Wavelength (nm) | 1260~1650 | |||||
Insertion Loss (dB) | 4.5 | 8.1 | 11.6 | 15.0 | 18.0 | 21.5 |
Loss Uniformity (dB) | 0.8 | 1.5 | 1.5 | 2.0 | 2.5 | 2.5 |
Return Loss (dB) | 55 | 55 | 55 | 55 | 55 | 55 |
PDL (dB) | 0.2 | 0.2 | 0.4 | 0.4 | 0.4 | 0.4 |
Directivity (dB) | 55 | 55 | 55 | 55 | 55 | 55 |
Fiber Length (m) | 1.0 or customized | |||||
Fiber Type | Corning SMF-28e or customized | |||||
Wavelength Dependent Loss (dB) | 0.5 | 0.5 | 0.5 | 0.5 | 0.5 | 0.5 |
Temperature Stability (-40~+85°C) (dB) | 0.5 | 0.5 | 0.5 | 0.5 | 0.5 | 0.5 |
Operating Temperature (°C) | -40~+85°C | |||||
Storage Temperature (°C) | -40~+85°C |
Package Dimensions:
Size L×W×H (mm) | Port | ||||||
60×4×7 | 1×2 | 2×2 | 1×4 | 2×4 | 1×8 | 2×8 | |
60×4×12 | 1×16 | 2×16 | |||||
80×6×20 | 1×32 | 2×32 | |||||
100×6×40 | 1×64 | 2×64 |
Ordering Information:
Brand | LW |
Name | PLC: PLC Splitter |
Package | B: blockless |
Port | 12: 1×2 14: 1×4 18: 1×8 116: 1×16 132: 1×32 164: 1×64 22: 2×2 24: 2×4 28: 2×8 216: 2×16 232: 2×32 264: 2×64 |
Cable Length | 0.5: 0.5m 1: 1m 1.5: 1.5m 2: 2m; etc |
Connector | SU: SC/UPC SA: SC/APC FU: FC/UPC FA: FC/APC LU: LC/UPC LA: LC/APC None=without connectors |